1. Power cable | 2. Raw water inlet hose | 3. Waste water | 4. Prefilter |
5. Drain clamp | 6. Three way valve | 7. Raw water supply valve | 8. Sink faucet hose |

Step 1
First install the supplied Three way valve (6) between the Raw water supply valve (7) and the Sink faucet hose (8).
To do this, first turn off the Raw water supply valve (7) under the sink. Then unscrew the Sink faucet hose (8).
After, install the Three way valve (6) between them. Now insert the Raw water inlet hose (2), into the Raw water inlet (labelled “lN”), and then screw the Three way valve nut as shown in figures A-B-C.

Step 2
Attach the supplied Drain clamp (5), including the foam gasket, just above the bend in the waste water pipe.
Then remove the front screw connection and drill a hole using a 6 mm drill bit.
Now screw in the screw connection back on and insert the Waste water outlet hose (3) into the Waste water outlet (labelled “OUT”), until it clicks into place

Step 3
Insert the supplied Prefilter (4) between the Three way valve (6) and the machine.
To do this, simply split the Raw water inlet hose (2) under the sink and insert the Prefilter (4) in between.
Please pay attention to the direction of the arrow labeled on the Prefilter.

Step 4
Turn the Raw water supply valve (7) (cold water) connection back on.

Step 5
Before inserting the Power plug (1) into the power socket, please confirm that the input voltage is 220V, the minimum current of the socket is greater than 10A, and keep the power plug and hands dry.

Step 6
Before use, rinse the filter cartridges:
Plug in the purifier, and will start water purification automatically.
Place a container (1.5L+) under the water outlet.
Press and hold the water button for 3 seconds until it beeps and starts draining.
Repeat the drainage process 3 times. Once completed, the purifier is ready for use.